Search Criteria

NSN/NIIN No.:
Part No. :
(13-16 digit NSN/9 digit NIIN)
5985-00-557-92325985-00-557-9226
NSNDescriptionAssign Date
5985-00-557-9228LINE,RADIO FREQUENCY TRANSMISSIO11/11/1974
NSNDescriptionDetailOpen Solicitations
5985-00-557-9228LINE,RADIO FREQUENCY TRANSMISSIO0
CompanyAward DateQuantityPriceContractDelivery Date
Free Trial05/09/1988Free TrialFree TrialN0010488G0153
Free Trial03/01/1987Free TrialFree TrialN0010487TY802
Free Trial11/01/1986Free TrialFree TrialN0010486MXZ56
For additional information Register for Free Trial
Part NumberCompanyCAGE
2836927NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY10001
For additional information Register for Free Trial
NameValue
OVERALL LENGTH15.500 INCHES
OUTSIDE DIAMETER0.141 INCHES NOMINAL
CONDUCTOR SIZE19 AWG
CHARACTERISTIC IMPEDANCE IN OHMS50.0
CONDUCTOR QUANTITY2
CAPACITANCE IN PICOFARADS PER UNIT LENGTH29.2 PER FOOT
INSULATION SPACER SHAPECIRCULAR
INSULATION SPACER OUTSIDE DIAMETER0.118 INCHES NOMINAL
ACCOMMODATED CONDUCTOR TYPECOAXIAL
MATERIALCOPPER
For additional information Register for Free Trial
CodeDefinition
ACQUISITION METHOD CODE.
'All Departments1SUITABLE FOR COMPETITIVE ACQUISITION.
ACQUISITION METHOD SUFFIX CODE.
'All DepartmentsGTHE GOVERNMENT HAS UNLIMITED RIGHTS TO THE TECHNICAL DATA AND THE DATA PACKAGE IS COMPLETE. VALID AMCS: 1 AND 2.
MAJOR ORGANIZATIONAL ENTITY.
NavyDNNavy
Defense Logistics Agency.DSDefense Logistics Agency.
PRICE
All DepartmentsPrice307.36
PRECIOUS METALS INDICATOR CODES.
All DepartmentsSItem contains silver.
CRITICALITY CODE.
All DepartmentsXThe item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
AUTOMATIC DATA PROCESSING EQUIPMENT.
All Departments0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9).
ELECTROSTATIC DISCHARGE CODE.
All Departments
HAZARDOUS MATERIALS INDICATOR CODE.
All DepartmentsPIndicates there is no information in the HMIRS; however, the NSN is in a FSC in Table II of Federal Standard 313 and a MSDS may be required by the user. The requirement for a MSDS is dependent on a hazard determination of the supplier or the intended end use of the product.
DEMILITARIZATION CODE.
All DepartmentsDUSML Items – DEMIL required. Destroy item and components to prevent restoration or repair to a usable condition. (Note 5).
For additional information Register for Free Trial
LINE,RADIO FREQUENC THE USE OF ANY CLASS I OZONE-DEPLETING SUBSTANCE (ODS) IN THE DESIGN, MANUFACTURING, TESTING, CLEANING, OR ANY OTHER PROCESS FOR THIS ITEM UNDER ANY MILITARY OR FEDERAL SPECIFICATION, STANDARD OR DRAWING REFERENCED IN THIS ITEM DESCRIPTION IS "PROHIBITED" UNLESS THE SEPARATE WRITTEN APPROVAL OF THE CONTRACTING OFFICER IS OBTAINED. THIS PROHIBITION SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT DOES NOT ALLEVIATE ANY PRODUCT PERFORMANCE REQUIREMENTS. THIS DOES NOT APPLY TO COMMERCIAL ITEMS, AS DEFINED IN "FAR 11.001" OR TO PART-NUMBERED- ONLY ITEMS. IF THE APPLICABLE (OEM OR MILITARY) DRAWING, SPECIFICATION, STANDARD, OR QUALITY ASSURANCE PROVISION (QAP) SPECIFIES AN ACCEPTABLE QUALITY LEVEL (AQL), THE SAMPLING ACCEPTANCE NUMBER SHALL BE REDUCED TO ZERO (0). FOR EXAMPLE, IF THE ACCEPT REJECT CRITERIA IS ACCEPT ON (3) DEFECTS AND REJECT ON (4) DEFECTS, THE NEW ACCEPT REJECT CRITERIA IS ACCEPT ON (0) DEFECTS AND REJECT THE ENTIRE LOT ON (1) DEFECT. EVEN THOUGH THE ACCEPTANCE LEVEL IS ELIMINATED, THE SAMPLE SIZE REMAINS THE SAME. FULL AND OPEN COMPETITION APPLIES. DLAD PROVISION 52.211-9009 IS APPLICABLE TO THIS SOLICITATION, THEREFORE SURPLUS MATERIAL WILL NOT BE CONSIDERED. IF PRESENT IN THE SOLICITATION, PROVISION 52.211-9003 AND CLAUSE 52.211-9000 ARE NOT APPLICABLE.