| CONNECTION TYPE | THREADED EXTERNAL PIPE 1ST END |
| THREADED EXTERNAL PIPE 2ND END |
| MEDIA FOR WHICH DESIGNED | AIR SINGLE RESPONSE |
| MEASURING METHOD AND LENGTH | 156.000 INCHES NOMINAL OVERALL |
| CROSS-SECTIONAL SHAPE STYLE | ROUND |
| TEMP RATING | -65.0 DEG FAHRENHEIT SINGLE RESPONSE |
| BURST TEST PRESSURE | 900.0 POUNDS PER SQUARE INCH |
| OUTER COVERING ENVIRONMENTAL PROTECTION | ABRASION RESISTANT AND |
| MILDEW RESISTANT AND |
| OZONE RESISTANT AND |
| COLD RESISTANT AND |
| FUEL RESISTANT |
| LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED COTTON CORD AND |
| OUTER LAYER RUBBER IMPREGNATED BRAIDED RAYON CORD |
| INSIDE DIAMETER | 0.375 INCHES NOMINAL |
| OUTSIDE DIAMETER | 0.750 INCHES NOMINAL |
| INSIDE SURFACE CONDITION | SMOOTH |
| CONNECTION STYLE | INVERTED FLARE 1ST END |
| INVERTED FLARE 2ND END |
| SEAT ANGLE | 30.0 DEGREES 1ST END |
| 30.0 DEGREES 2ND END |
| END CONNECTION DESIGN | STRAIGHT 1ST END |
| STRAIGHT 2ND END |
| THREAD SERIES DESIGNATOR | UNF 1ST END |
| NPTF 2ND END |
| NOMINAL THREAD SIZE | 0.500 INCHES 1ST END |
| 0.250 INCHES 2ND END |
| THREAD QUANTITY PER INCH | 14 1ST END |
| 18 2ND END |
| THREAD DIRECTION | RIGHT-HAND 1ST END |
| RIGHT-HAND 2ND END |
| SPEC/STD CONTROLLING DATA | |
| MANUFACTURERS CODE | 81349 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-DTL-3992 |