| AMBIENT TEMP AT FULL RATED POWER | 100.0 CELSIUS |
| BODY LENGTH | 0.264 INCHES NOMINAL |
| INCLOSURE TYPE | ENCASED |
| MAXIMUM OPERATING TEMP | 125.0 CELSIUS |
| MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | 0.164 INCHES |
| MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| MOUNTING THREAD QUANTITY | 32 PER INCH |
| PROBE DIAMETER | 0.012 INCHES NOMINAL |
| PROBE LENGTH | 12.000 INCHES NOMINAL |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.0 TO 1.0 ALL RESISTANCE-TEMPERATURE POINTS |
| STYLE DESIGNATOR | PROBE |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 110.0 CELSIUS SECOND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 95.0 CELSIUS FIRST RESISTANCE-TEMPERATURE POINT |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| THREAD LENGTH | 0.125 INCHES NOMINAL |
| WIDTH ACROSS FLATS | 0.250 INCHES NOMINAL |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -1.0 TO 1.0 |
| ZERO POWER RESISTANCE | 55.330 KILOHMS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.759 KILOHMS SECOND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 678.3 KILOHMS FIRST RESISTANCE-TEMPERATURE POINT |