5910-00-558-9146 CAPACITOR,FIXED,MICA DIELECTRIC Index 5910-00-558-9148 CAPACITOR,FIXED,ELECTROLYTIC

National Stock Number:
5910-00-558-9147

Federal Supply Class:
5910

National Item Identification Number:
005589147

Description:
CAPACITOR,FIXED,ELECTROLYTIC

Detail:
A capacitor, whose capacitance value cannot be adjusted or varied, having a chemically formed film as the dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.


Manufacturer Information:
352250004173H0203THALES NEDERLAND B.V.
CE13C090Q81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M62-02-06681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MILC62-281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
VBE778B9MQH0203THALES NEDERLAND B.V.


Techincal Specification:
ELECTRICAL POLARIZATIONPOLARIZED
BODY DIAMETER0.687 INCHES NOMINAL
BODY LENGTH2.187 INCHES NOMINAL
BODY STYLEW/O MTG FACILITIES, AXIAL TERMINALS
CAPACITANCE VALUE PER SECTION9.000 MICROFARADS SINGLE SECTION
CAPACITIVE ELECTRODE MATERIALALUMINUM
CASE INSULATION MATERIALPLASTIC
DC LEAKAGE AT REFERENCE TEMP190.000 MICROAMPERES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT12.0000
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION400.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP-40.0 CELSIUS MINIMUM AND 85.0 CELSIUS MAXIMUM
RELIABILITY INDICATORESTABLISHED
SCHEMATIC DIAGRAM DESIGNATORELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL DIAMETER0.040 INCHES NOMINAL
TERMINAL LENGTH2.000 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY2 UNINSULATED WIRE LEAD
TEST DATA DOCUMENT81349-MILC 62 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TOLERANCE RANGE PER SECTION-10.00 TO 50.00 PERCENT SINGLE SECTION