CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL10.0 AMPERES INDUCTIVE LOAD AND 15.0 AMPERES RESISTIVE LOAD DC AT SEA LEVEL |
CONTACT SWITCHING ACTION | BREAKS BEFORE MAKES EACH SECTION PERIPHERY |
CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL28.0 DC AT SEA LEVEL |
FIRST FLAT LENGTH | 0.690 INCHES NOMINAL SINGLE ACTUATOR |
FLAT HEIGHT | 0.182 INCHES MINIMUM AND 0.192 INCHES MAXIMUM SINGLE ACTUATOR |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK RESISTANT |
INDIVIDUAL SECTION QUANTITY | 2 |
OVERALL DIAMETER | 2.130 INCHES MAXIMUM |
OVERALL LENGTH | 3.150 INCHES NOMINAL |
MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.469 INCHES SINGLE MOUNTING FACILITY |
NONTURN DEVICE TYPE | SLOTTED BUSHING AT 6:00 O'CLOCK |
OPERATING TEMP RANGE | -55.0 TO 125.0 CELSIUS |
POLE QUANTITY | 1 EACH SECTION PERIPHERY |
SHAFT DIAMETER | 0.248 INCHES MINIMUM AND 0.252 INCHES MAXIMUM SINGLE ACTUATOR |
SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
SHAFT LENGTH | 0.750 INCHES NOMINAL SINGLE ACTUATOR |
STYLE DESIGNATOR | TAP, CIRCULAR, BUSHING MOUNT |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 3 SINGLE ACTUATOR |
SWITCH ACTUATOR POSITIONING INCREMENT | 90.0 DEGREES SINGLE ACTUATOR |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP SYMMETRICAL |
TERMINAL TYPE | SCREW |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.470 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNS SINGLE MOUNTING FACILITY |
THROW QUANTITY | 3 EACH SECTION PERIPHERY |