NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC AND |
| 20.0 AMPERES DC RESISTIVE LOAD |
| 15.0 AMPERES DC INDUCTIVE LOAD |
| 5.0 AMPERES AC AND |
| 5.0 AMPERES DC LAMP LOAD |
| 20.0 AMPERES AC AND |
| 20.0 AMPERES DC MOTOR LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.531 INCHES MAXIMUM |
OVERALL WIDTH | 1.531 INCHES MAXIMUM |
OVERALL HEIGHT | 2.087 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
CUBIC MEASURE | 4.891 CUBIC INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CASE MATERIAL | METAL |