DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
CRITICALITY CODE JUSTIFICATION | FEAT |
CUBIC MEASURE | 0.517 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | POLARIZED |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND 2.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OVERALL HEIGHT | 0.620 INCHES MINIMUM AND 0.660 INCHES MAXIMUM |
OVERALL LENGTH | 1.360 INCHES MINIMUM AND 1.390 INCHES MAXIMUM |
OVERALL WIDTH | 0.790 INCHES MINIMUM AND 0.810 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
SPECIAL FEATURES | FAILURE RATE 5.0 PERCENT PER 10,000 CYCLES |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
WINDING DC RESISTANCE RATING | 4.3 KILOHMS MINIMUM AND 5.8 KILOHMS MAXIMUM SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |