DUTY TYPE | INTERMITTENT |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 30.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
OVERALL HEIGHT | 1.500 INCHES NOMINAL |
OVERALL LENGTH | 3.870 INCHES NOMINAL |
OVERALL WIDTH | 1.500 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 8.0 MILLIAMPERES DC SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 3A1B |
WINDING DC RESISTANCE RATING | 3.0 KILOHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 10 PIN ALL FUNCTIONS |
TIME DELAY | 0.02 SECONDS NOMINAL FIXED OPERATE TIME |
TIME DELAY | 0.03 SECONDS NOMINAL FIXED RELEASE TIME |