| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 11 SCREW ALL FUNCTIONS |
| TIME DELAY | 0.60 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.80 SECONDS MAXIMUM FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 4.235 INCHES MAXIMUM |
| OVERALL WIDTH | 4.218 INCHES MAXIMUM |
| OVERALL HEIGHT | 4.280 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 76.454 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CASE MATERIAL | METAL |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC RESISTIVE LOAD |