| TERMINAL TYPE AND QUANTITY | 19 TAB, SOLDER LUG |
| WINDING OPERATING VOLTAGE | 28.00 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 22.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 28.00 DC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 44.00 DC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| WINDING OPERATING CURRENT | 3.5 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| 2.0 AMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| 1.5 AMPERES DC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| 1.5 AMPERES DC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| WINDING POWER RATING | 98.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| 44.00 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| 42.00 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| 66.00 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 5 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| NOMINAL THREAD SIZE | 0.164 INCHES SINGLE GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.160 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| INCLOSURE TYPE | FULLY INCLOSED |
| BODY LENGTH | 4.520 INCHES MAXIMUM |
| BODY HEIGHT | 2.200 INCHES MAXIMUM |
| BODY WIDTH | 4.270 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |