5950-00-581-2490 TRANSFORMER,POWER Index 5950-00-581-2493 REACTOR

National Stock Number:
5950-00-581-2491

Federal Supply Class:
5950

National Item Identification Number:
005812491

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
135603310001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
3868173386FREED TRANSFORMER CO
BX-926385323BALTIMORE TRANSFORMER CO


Techincal Specification:
BODY HEIGHT4.875 INCHES NOMINAL
BODY LENGTH3.594 INCHES NOMINAL
BODY WIDTH3.062 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.938 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING400.0 HERTZ NOMINAL SINGLE COMPONENT
INCLOSURE TYPEHERMETICALLY SEALED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING METHODFLANGE AND UNTHREADED HOLE SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENT1.36 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 3 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT295.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT2.2 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE108.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL AND 122.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE110.00 AC VOLTS NOMINAL AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE24.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE63.00 AC VOLTS NOMINAL AND 66.50 AC VOLTS NOMINAL AND 140.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
TERMINAL TYPE AND QUANTITY14 SOLDER STUD