5910-00-581-9197 CAPACITOR,VARIABLE,GLASS DIELECT Index 5950-00-581-9201 REACTOR

National Stock Number:
5950-00-581-9199

Federal Supply Class:
5950

National Item Identification Number:
005819199

Description:
TRANSFORMER,POWER

Detail:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.


Manufacturer Information:
2A2-24480089EMERSON ELECTRIC CO WHITE-RODGERS DIV
2A2-244D9368WESTDEUTSCHE WERKZEUGMASCHINEN AG
63119806424ALLIANT TECHSYSTEMS OPERATIONS LLC
63119856232LOCKHEED MARTIN CORPORATION
D63119882199ROHDE & SCHWARZ USA, INC.
BTC290289870BERKSHIRE TRANSFORMER
W1019465180UNISYS CORP SYSTEMS DEVELOPMENT


Techincal Specification:
BODY HEIGHT4.500 INCHES MAXIMUM
BODY LENGTH5.000 INCHES MAXIMUM
BODY WIDTH4.031 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.094 INCHES MINIMUM AND 3.141 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH2.890 INCHES MINIMUM AND 2.922 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
FREQUENCY RATING50.0 HERTZ MINIMUM AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
INCLOSURE TYPEFULLY INCLOSED
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
MAXIMUM OPERATING TEMP170.0 CELSIUS
MOUNTING FACILITY QUANTITY4 SINGLE GROUP
MOUNTING SLOT WIDTH0.213 INCHES MINIMUM AND 0.223 INCHES MAXIMUM SINGLE GROUP
MOUNTING METHODSLOT SINGLE GROUP
RELIABILITY INDICATORNOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING AND SIX SECONDARY WINDINGS
WINDING FUNCTION AND QUANTITY1 PRIMARY AND 6 SECONDARY SINGLE COMPONENT
WINDING OPERATING CURRENT300.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING CURRENT2.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING CURRENT2.8 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING CURRENT600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING VOLTAGE45.00 AC VOLTS NOMINAL AND 705.00 AC VOLTS NOMINAL AND 1.29 AC KILOVOLTS NOMINAL AND 1.88 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY
WINDING OPERATING VOLTAGE5.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY
WINDING OPERATING VOLTAGE56.30 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY
WINDING OPERATING VOLTAGE6.30 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY
WINDING POWER RATING565.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
WINDING SHIELDING METHODINTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
WINDING POWER RATING10.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
WINDING POWER RATING17.6 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
WINDING POWER RATING3.78 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
TERMINAL TYPE AND QUANTITY19 TAB, SOLDER LUG
TEST DATA DOCUMENT56232-631198 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)


Click here to Register for Free 30-day Trial