| TERMINAL TYPE AND QUANTITY | 11 THREADED STUD |
| WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND |
| 4 SECONDARY SINGLE COMPONENT |
| INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
| MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS |
| NOMINAL THREAD SIZE | 0.250 INCHES ALL GROUPINGS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.720 INCHES MINIMUM AND |
| 3.780 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.970 INCHES MINIMUM AND |
| 3.030 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| BODY LENGTH | 5.375 INCHES MINIMUM AND |
| 5.500 INCHES MAXIMUM |
| BODY HEIGHT | 4.562 INCHES MINIMUM AND |
| 4.750 INCHES MAXIMUM |
| BODY WIDTH | 4.375 INCHES MINIMUM AND |
| 4.500 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
| MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |