5970-00-565-8936 INSULATION SLEEVING,ELECTRICAL Index 6625-00-565-8943 TEST SET SUBASSEMBLY,ELECTRICAL

National Stock Number:
5970-00-565-8938

Federal Supply Class:
5970

National Item Identification Number:
005658938

Description:
INSULATION SLEEVING,ELECTRICAL,S

Detail:
A rigid or flexible tubing having other than uniform fabricated shapes or forms. It is specifically designed to prevent any undesirable flow of current between conductors or between conductors and other objects. Includes shrinkable type items. Excludes items not having rated electrical characteristics. Also excludes BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; and INSULATION SLEEVING, ELECTRICAL.


Manufacturer Information:
462A011-3-0006090TE CONNECTIVITY CORPORATION
462A011-3-00-006090TE CONNECTIVITY CORPORATION


Techincal Specification:
DISTANCE FROM INTERSECTING CENTERLINE OF MAIN BODY TO END OF FIRST BRANCH0.900 INCHES MINIMUM AND 1.100 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND FIRST BRANCH CENTERLINES IN DEG25.0 MINIMUM AND 35.0 MAXIMUM AFTER UNRESTRICTED RECOVERY
ANGLE BETWEEN MAIN BODY AND SECOND BRANCH CENTERLINES IN DEG25.0 MINIMUM AND 35.0 MAXIMUM AFTER UNRESTRICTED RECOVERY
COLORBLACK
FIRST BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FIRST BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
FIRST BRANCH WALL THICKNESS0.032 INCHES MINIMUM AND 0.048 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
FLEXIBILITYFLEXIBLE
MAIN BODY WALL THICKNESS0.048 INCHES MINIMUM AND 0.072 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.260 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MAIN BODY INSIDE DIAMETER0.520 INCHES MINIMUM AS SUPPLIED
MAIN BODY OVERALL LENGTH1.698 INCHES MINIMUM AND 2.062 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
MATERIAL DOCUMENT AND CLASSIFICATIONRT-301, RAYCHEM CORP MFR REF SINGLE MATERIAL RESPONSE
MATERIALPLASTIC POLYOLEFIN
RELIABILITY INDICATORNOT ESTABLISHED
SECOND BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SECOND BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
SECOND BRANCH WALL THICKNESS0.032 INCHES MINIMUM AND 0.048 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
SPECIAL FEATURESINCLUDES MOLDING PORTS
STYLE DESIGNATORTRANSITION-1 TO 3 CABLES
THIRD BRANCH INSIDE DIAMETER0.140 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY
THIRD BRANCH INSIDE DIAMETER0.260 INCHES MINIMUM AS SUPPLIED
THIRD BRANCH WALL THICKNESS0.032 INCHES MINIMUM AND 0.048 INCHES MAXIMUM AFTER UNRESTRICTED RECOVERY