| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| FLANGE QUANTITY | 2 |
| FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY |
| FLANGE STYLE | COVER TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| MATERIAL | ALUMINUM ALLOY ALL FLANGE |
| WAVEGUIDE OUTSIDE WIDTH | 0.996 INCHES MINIMUM AND |
| 1.004 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 0.896 INCHES MINIMUM AND |
| 0.904 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 0.396 INCHES MINIMUM AND |
| 0.404 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.496 INCHES MINIMUM AND |
| 0.504 INCHES MAXIMUM |
| BEND ANGLE IN DEG | 90.0 ALL BENDS E-PLANE |
| SURFACE TREATMENT | OXIDE FILM ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM AND |
| 1.006 INCHES MAXIMUM ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM AND |
| 0.506 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM AND |
| 1.640 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM AND |
| 1.640 INCHES MAXIMUM ALL FLANGES |
| FLANGE DEPTH | 0.422 INCHES MINIMUM AND |
| 0.453 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND |
| 0.172 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY |
| MAXIMUM OPERATING PRESSURE | 20.0 POUNDS PER SQUARE INCH GAGE |
| INSERTION LOSS IN DECIBELS | 0.10 |
| VOLTAGE STANDING WAVE RATIO | 1.10 |
| SPECIAL FEATURES | TUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED |
| THE MANUFACTURERS DATA | |
| MANUFACTURERS CODE | 10001 |
| DESIGN CONTROL REFERENCE | 2835877 |