1610-00-562-1414 BRUSHBLOCK Index 1560-00-562-1417 CUSHION

National Stock Number:
5985-00-562-1416

Federal Supply Class:
5985

National Item Identification Number:
005621416

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
257597510001NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER


Techincal Specification:
BEND ANGLE IN DEG70.0 SINGLE BEND E-PLANE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE CONNECTING HOLE DIAMETER0.166 INCHES MINIMUM AND 0.172 INCHES MAXIMUM ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE INSIDE DIAMETER1.253 INCHES MINIMUM AND 1.360 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.610 INCHES MINIMUM AND 0.640 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH1.860 INCHES MINIMUM AND 1.890 INCHES MAXIMUM ALL FLANGES
FLANGE QUANTITY2
FLANGE STYLECHOKE TYPE ALL FLANGES
FLEXIBILITYRIGID SINGLE TUBING SEGMENT
INSERTION LOSS IN DECIBELS0.05
MATERIALALUMINUM ALLOY ALL FLANGE
MATERIALALUMINUM ALLOY SINGLE TUBING SEGMENT
MAXIMUM OPERATING PRESSURE10.0 POUNDS PER SQUARE INCH GAGE
SPECIAL FEATURESTUBING WALL CONSTRUCTION CAN ALSO BE LAMINATED
VOLTAGE STANDING WAVE RATIO2.00
WAVEGUIDE INSIDE HEIGHT0.493 INCHES MINIMUM AND 0.501 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH1.118 INCHES MINIMUM AND 1.126 INCHES MAXIMUM
WAVEGUIDE OFFSET DISTANCE3.328 INCHES MINIMUM AND 3.358 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.621 INCHES MINIMUM AND 0.629 INCHES MAXIMUM
WAVEGUIDE OUTSIDE WIDTH1.246 INCHES MINIMUM AND 1.254 INCHES MAXIMUM
WAVEGUIDE LONGER OFFSET DISTANCE3.507 INCHES NOMINAL
STYLE DESIGNATORBEND TYPE
SURFACE TREATMENTOXIDE FILM ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT


Click here to Register for Free 30-day Trial