1650-00-587-2573 DRIVE ASSEMBLY,BUNGEE TRIM Index 5340-00-587-2582 STRIKE,CATCH

National Stock Number:
5985-00-587-2574

Federal Supply Class:
5985

National Item Identification Number:
005872574

Description:
WAVEGUIDE ASSEMBLY

Detail:
An item consisting of one or more definite lengths of straight or formed, flexible or rigid, prefabricated hollow tubing of conductive material. The tubing has a predetermined cross section and is designed to guide or conduct high frequency electromagnetic energy through its interior. One or more ends are terminated. May include common mounting of a SWITCH, WAVE GUIDE, a DUMMY LOAD, ELECTRICAL and other components such as waveguide section, cable terminal chamber and the like. Excludes COUPLER, ROTARY, RADIO FREQUENCY; COUPLER, DIRECTIONAL; ADAPTER, WAVEGUIDE; and TUNER, WAVEGUIDE.


Manufacturer Information:
253626-182577RAYTHEON COMPANY
C23549154647MICROTECH INC
TS645-420-106351MICROWAVE ENGINEERING CORPORATION
TS64542006351MICROWAVE ENGINEERING CORPORATION


Techincal Specification:
STYLE DESIGNATORBEND TYPE
CROSS-SECTIONAL SHAPE STYLEINTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR
TUBING WALL CONSTRUCTION STYLESEAMLESS SINGLE TUBING SEGMENT
FLANGE QUANTITY2
FLANGE CONNECTING FACILITY AND QUANTITY4 UNTHREADED HOLE ALL FLANGES SINGLE CONNECTION FACILITY
FLANGE STYLECOVER TYPE ALL FLANGES
FLEXIBILITYFLEXIBLE SINGLE TUBING SEGMENT
MATERIALCOPPER ALLOY SINGLE TUBING SEGMENT
RUBBER NATURAL SINGLE TUBING JACKET
WAVEGUIDE LONGER OFFSET DISTANCE9.810 INCHES NOMINAL
WAVEGUIDE OFFSET DISTANCE4.060 INCHES NOMINAL
WAVEGUIDE OUTSIDE WIDTH0.996 INCHES MINIMUM AND
1.004 INCHES MAXIMUM
WAVEGUIDE INSIDE WIDTH0.896 INCHES MINIMUM AND
0.904 INCHES MAXIMUM
WAVEGUIDE INSIDE HEIGHT0.396 INCHES MINIMUM AND
0.404 INCHES MAXIMUM
WAVEGUIDE OUTSIDE HEIGHT0.496 INCHES MINIMUM AND
0.504 INCHES MAXIMUM
SURFACE TREATMENTSILVER SINGLE TUBING SEGMENT INSIDE SURFACES
PRIMER AND
PAINT ALL FLANGE OUTSIDE SURFACES
FLANGE INSIDE WIDTH1.003 INCHES MINIMUM AND
1.006 INCHES MAXIMUM ALL FLANGES
FLANGE INSIDE HEIGHT0.503 INCHES MINIMUM AND
0.506 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE WIDTH1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM ALL FLANGES
FLANGE OUTSIDE HEIGHT1.610 INCHES MINIMUM AND
1.640 INCHES MAXIMUM ALL FLANGES
FLANGE DEPTH0.423 INCHES MINIMUM AND
0.453 INCHES MAXIMUM ALL FLANGES
FLANGE CONNECTING HOLE DIAMETER0.169 INCHES MINIMUM AND
0.172 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES
MAXIMUM OPERATING PRESSURE120.0 POUNDS PER SQUARE INCH GAGE
INSERTION LOSS IN DECIBELS0.10
VOLTAGE STANDING WAVE RATIO1.15
SPECIAL FEATURESFREQUENCY RANGE 8.2 TO 12.4 GHZ; TEMPERATURE RANGE MINUS 55.0 TO PLUS 125.0 DEG C; CADMIUM PLATE FLANGE FACES; 200 KW MAX POWER
PRECIOUS MATERIALSILVER
PRECIOUS MATERIAL AND LOCATIONINTERNAL SURFACES SILVER
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT


Click here to Register for Free 30-day Trial