| STYLE DESIGNATOR | STRAIGHT TYPE |
| CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR EXTERNAL, RECTANGULAR |
| TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
| FLANGE QUANTITY | 2 |
| FLANGE CONNECTING FACILITY AND QUANTITY | 8 UNTHREADED HOLE ALL FLANGES ALL CONNECTION FACILITIES |
| FLANGE STYLE | CONTACT TYPE ALL FLANGES |
| FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
| MATERIAL | COPPER ALLOY ALL TUBING SEGMENT AND FLANGE |
| WAVEGUIDE LENGTH | 4.000 INCHES NOMINAL |
| WAVEGUIDE OUTSIDE WIDTH | 1.246 INCHES MINIMUM AND |
| 1.254 INCHES MAXIMUM |
| WAVEGUIDE INSIDE WIDTH | 1.118 INCHES MINIMUM AND |
| 1.126 INCHES MAXIMUM |
| WAVEGUIDE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND |
| 0.501 INCHES MAXIMUM |
| WAVEGUIDE OUTSIDE HEIGHT | 0.621 INCHES MINIMUM AND |
| 0.629 INCHES MAXIMUM |
| SURFACE TREATMENT | SILVER ALL TUBING SEGMENT AND FLANGE INSIDE SURFACES |
| ENAMEL ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
| FLANGE INSIDE WIDTH | 1.122 INCHES NOMINAL ALL FLANGES |
| FLANGE INSIDE HEIGHT | 0.493 INCHES MINIMUM AND |
| 0.501 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE WIDTH | 2.480 INCHES MINIMUM AND |
| 2.520 INCHES MAXIMUM ALL FLANGES |
| FLANGE OUTSIDE HEIGHT | 1.730 INCHES MINIMUM AND |
| 1.770 INCHES MAXIMUM ALL FLANGES |
| FLANGE DEPTH | 0.480 INCHES MINIMUM AND |
| 0.520 INCHES MAXIMUM ALL FLANGES |
| FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM AND |
| 0.171 INCHES MAXIMUM ALL FLANGES ALL CONNECTION FACILITIES |
| MAXIMUM OPERATING PRESSURE | 5.0 POUNDS PER SQUARE INCH GAGE |
| INSERTION LOSS IN DECIBELS | 0.03 |
| VOLTAGE STANDING WAVE RATIO | 1.05 |
| PRECIOUS MATERIAL | SILVER |
| PRECIOUS MATERIAL AND LOCATION | INTERNAL SURFACES SILVER |