6145-01-356-6378 WIRE,ELECTRICAL Index 8010-01-356-6380 POLYURETHANE COATING

National Stock Number:
6145-01-356-6379

Federal Supply Class:
6145

National Item Identification Number:
013566379

Description:
CABLE,POWER,ELECTRICAL

Detail:
Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY or CORD, ELECTRICAL. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.


Manufacturer Information:
CO-02MOE(1/8-1/20)SJO51081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M3432-02MOE(1/8-1/20)SJO51081349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-C-343281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-DTL-343281349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
COLORBLACK FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR
COLORWHITE FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR
CONDUCTOR ARRANGEMENT AND QUANTITY2 SINGLES
CONDUCTOR FORMSTRANDED ALL CONDUCTORS
CONDUCTOR QUANTITY2
CROSS SECTION OUTSIDE DIAMETER0.510 INCHES NOMINAL
CROSS-SECTIONAL SHAPE STYLEROUND
MATERIAL DOCUMENT AND CLASSIFICATIONASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIALCOPPER SECOND POSITION SHIELD BRAID METALLIC CABLE
MATERIALRUBBER BUTADIENE-STYRENE CLASS SBR FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIALRUBBER CHLOROPRENE CLASS CR THIRD POSITION JACKET CABLE
ROUND CONDUCTOR SIZE20 AWG SECOND CONDUCTOR
ROUND CONDUCTOR SIZE8 AWG FIRST CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR30 FIRST CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR36 SECOND CONDUCTOR
STRAND QUANTITY PER CONDUCTOR168 FIRST CONDUCTOR
STRAND QUANTITY PER CONDUCTOR41 SECOND CONDUCTOR
SURFACE TREATMENTTIN CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENTTIN SECOND POSITION SHIELD BRAID METALLIC CABLE
TEMP RATING-40.0 CELSIUS AND 75.0 CELSIUS
VOLTAGE RATING600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS