INSTALLATION DESIGN | PANEL |
INDICATOR TYPE | DIAL W/POINTER |
MEASUREMENT RANGE | 0.0 TO 150.0 AMPERES, AC SINGLE INDICATOR SINGLE RANGE |
ACCURACY IN PERCENT | -2.5 TO 2.5 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
POINTER COLOR | WHITE SINGLE INDICATOR SINGLE RANGE |
DIAL SCALE MARKING COLOR | YELLOW SINGLE INDICATOR SINGLE RANGE |
BACKGROUND COLOR | BLACK SINGLE INDICATOR SINGLE RANGE |
MOVEMENT TYPE | MOVING IRON VANE |
MOVEMENT SUSPENSION METHOD | TAUT BAND |
CIRCUIT ATTACHMENT METHOD AND QUANTITY | 2 SOLDER STUD |
POWER SOURCE | EXTERNAL |
CIRCUIT CURRENT FOR WHICH DESIGNED | AC |
STYLE DESIGNATOR | ROUND FLUSH MTG |
METER BODY DIAMETER BEHIND MOUNTING FLANGE | 2.210 INCHES NOMINAL |
METER DEPTH BEHIND MOUNTING FLANGE | 1.086 INCHES NOMINAL |
OVERALL DIAMETER | 2.695 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE |
MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL |
MOUNTING ARRANGEMENT STYLE | THREE HOLE/STUD BOLT CIRCLE |
MOUNTING BOLT CIRCLE DIAMETER | 2.440 INCHES NOMINAL |
PANEL FOR WHICH DESIGNED | MAGNETIC |
CIRCUIT CONSTRUCTION TYPE | NONELECTRONIC |
NUCLEAR HARDNESS CRITICAL FEATURE | NONHARDENED |
FEATURES PROVIDED | ZERO ADJUSTER |
SPECIAL FEATURES | 1.2 AMP FULL SCALE DEFLECTION |
FSC APPLICATION DATA | TEST SET,ELECT. EQUIP. |